Control Parameter
|
|||
|
Battery charging setting
|
Gel
|
Sealed
|
Flooded
|
|
High Volt Disconnect
|
16V; x2/24V
|
16V; x2/24V
|
16V; x2/24V
|
|
Charging limit voltage
|
15.5V; x2/24V
|
15.5V; x2/24V
|
15.5V; x2/24V
|
|
Over Voltage Reconnect
|
15V; x2/24V
|
15V; x2/24V
|
15V; x2/24V
|
|
Equalization voltage
|
——
|
14.6V; x2/24V
|
14.8V; x2/24V
|
|
Boost voltage
|
14.2V; x2/24V
|
14.4V; x2/24V
|
14.6V; x2/24V
|
|
Float voltage
|
13.8V; x2/24V
|
13.8V; x2/24V
|
13.8V; x2/24V
|
|
Boost return voltage
|
13.2V; x2/24V
|
13.2V; x2/24V
|
13.2V; x2/24V
|
|
Low voltage reconnect
|
12.6V; x2/24V
|
12.6V; x2/24V
|
12.6V; x2/24V
|
|
Under voltage recover
|
12.2V; x2/24V
|
12.2V; x2/24V
|
12.2V; x2/24V
|
|
Under voltage warning
|
12V; x2/24V
|
12V; x2/24V
|
12V; x2/24V
|
|
Low voltage disconnect
|
11.1V; x2/24V
|
11.1V; x2/24V
|
11.1V; x2/24V
|
|
Discharging limits voltage
|
10.8V; x2/24V
|
10.8V; x2/24V
|
10.8V; x2/24V
|
|
Equalize duration
|
——
|
2hours
|
2hours
|
|
Boost duration
|
2hours
|
2hours
|
2hours
|
|
Parameter
|
|
|
Nominal System Voltage
|
12VDC / 24VDC Auto work
|
|
Rated Charge Current
|
45A
|
|
Rated Discharge Current
|
20A
|
|
Maximum Battery Voltage
|
32V
|
|
Max. Solar Input Voltage
|
Tracer-4215RN 150VDC
|
|
Max. PV input power
|
12V / 520W
24V / 1040W
|
|
Self-consumption*
|
<10mA(24V)
|
|
Charge Circuit Voltage Drop
|
≤0.26V
|
|
Discharge Circuit Voltage Drop
|
≤0.15V
|
|
Communication
|
TTL232 / 8pin RJ45
|
|
Mechanical
|
Parameter
|
|
Dimension
|
242 x 169x 91 / mm
|
|
Mounting holes
|
180 x 160 / mm
|
|
Mounting hole size
|
Φ5
|
|
Terminal
|
25mm2
|
|
Weight
|
2.05kg
|
|
Timer1
|
LED Digital No.
|
|
Disable
|
n
|
|
Dusk to Dawn, Load will be on all night
|
0
|
|
1
|
|
|
Load will be on for 2 hours after ten minutes delay since sunset
|
2
|
|
Load will be on for 3 hours after ten minutes delay since sunset
|
3
|
|
Load will be on for 4 hours after ten minutes delay since sunset
|
4
|
|
Load will be on for 5 hours after ten minutes delay since sunset
|
5
|
|
Load will be on for 6 hours after ten minutes delay since sunset
|
6
|
|
Load will be on for 7 hours after ten minutes delay since sunset
|
7
|
|
Load will be on for 8 hours after ten minutes delay since sunset
|
8
|
|
Load will be on for 9 hours after ten minutes delay since sunset
|
9
|
|
Load will be on for 10 hours after ten minutes delay since sunset
|
10
|
|
Load will be on for 11 hours after ten minutes delay since sunset
|
11
|
|
Load will be on for 12 hours after ten minutes delay since sunset
|
12
|
|
13
|
|
|
Load will be on for 14 hours after ten minutes delay since sunset
|
<span style="font-s
|